This product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values.
Capacitance measurement and non-contact voltage detection (NCV) are selected by pressing buttons. The UT202BT features a new design, high reliability and safety, as well as automatic range switching available for all functions. The dual backlit LCD display, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, and current/frequency.
There is an LED light on the underside of the test leads. It is powered by two 1.5V R03 AAA batteries.
The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree.
Parameters:
- measurement of AC/DC voltage, AC current, resistance, capacitance, temperature and circuit continuity
- Measurement of voltage and current frequency on the auxiliary display
- Non-contact electric field sensor (NCV)
- Dual LCD display with multi-segment backlight
- Increased acoustic and visual protection against voltages of 60V and above
- Automatic range switching
- Accuracy guaranteed within the range of 5% to 100% of the ranges
- Built-in LED torch
- Powered by two 1.5V AAA R03 batteries
Technical parameters:
To ensure measurement accuracy, operating temperature range: -18°C to 28°C
1a. AC current measurement (ranges/resolution/accuracy):
9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60)
- minimum detectable current: 0.01A
- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
- Overload protection at 60 Hz/> AC current measurement - LPF (range / resolution / accuracy):
6000A / 0.1A / 50Hz to 60Hz ±(4.0%+5) / 600A rms
1c. AC trip current measurement (range / resolution / accuracy):
99.99A / 0.01A / 50Hz to 60Hz ±(10%+10) / 600A rms
6000A / 0.1A / 50Hz ±0% / 60Hz ±60Hz rms
2a. AC voltage measurement (range / resolution / accuracy):
9.999V / 0.001V / 40Hz to 400Hz ±(0.8%+3)
99.99V / 0.010V / 40Hz to 400Hz ±(0.8%+3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3)
- The frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.
- Input impedance approx. 10 MΩ
- Overload protection at 600Vrms
- Minimum detectable voltage 0.6V
2b. AC-LPF voltage measurement (range / resolution / accuracy):
600 V / 0.1 V / 40 Hz to 400 Hz ±(2.0%+5) / 600 V rms
3. DC voltage measurement (range / resolution / accuracy):
9.999 V / 0.001 V / ±(0.5%+3)
99.99V / 0.01V / ±(0.5%+3)
600V / 0.1V / ±(0.5%+3) input
approx. 10MΩ
- overload protection at 600Vrms
- minimum detectable voltage 0.6V
4. Resistance measurement (ranges/resolution/accuracy):
999.9Ω / 0.1Ω / ±(0.8%+3)
9.999 kΩ / 0.001 kΩ / ±(0.8% + 3)
99.99kΩ / 0.01kΩ / 0.01kΩ /%+90kΩ /%+90kΩ />±9kΩ / 0.1kΩ / ±(0.8%+3)
9.999 MΩ / 0.001 MΩ / ±(1.5%+3)
99.99 MΩ / 0.01 MΩ / ±(2.0%+5)
- overload protection at 600 Vrms open-circuit voltage approx.
- 1V
5. Capacitance measurement (ranges/resolution/accuracy):
99.99 nF / 0.01 nF / ±(4.0%+10)
999.9 nF / 0.1 nF / ±(4.0%+10)
9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5)
99.99 μF / 0.01 μF / ±(4.0% + 5)
999.9 μF / 0.1 μF / ±(4.0% + 5)
9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10)
- overload protection at 600 Vrms
6. Checking circuit continuity:
- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
- open-circuit voltage approx. 3.0 V
- Overload protection at 600 Vrms
7. Temperature measurement:
-40°C~1000°C / ±(2.0%+5)
8. Non-contact electric field sensing (NCV):
- enables acoustic detection of live conductors using a buzzer and optical detection using an LED
Other parameters:
- jaw opening: 28mm
- measurement of maximum and minimum values: yes
- yes
- Yes, data hold, low battery indication (H/>>- and low data: battery voltage is less than 2.4 V; if the battery voltage is less than approx. 2.2 V, the device cannot be switched on
- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.
- Drop resistance: yes, 1 m
- Electromagnetic compatibility: RF ≤ 1 V/m, general accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified
- Operating altitude: ≤ 2000m and operating humidity <3000m
-: (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
- storage temperature and humidity: -20 to +60°C (≤ 80%RH)
- recommended calibration interval: 1 year
- 1-battery power supply: 5 V–2 V (R03)
- product dimensions: 201.5 × 47 × 28.5 mm
- Weight: approx. 241 g (including batteries);
- product colour: red and grey
Package contents:
- UT202BT clamp multimeter: 1 pc
- test leads: 1 pair
- temperature probe (K): 1 pc
- 2 x R03 instruction manuals
- User manual: 1 copy
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT211B Clamp Meter
This product comes with a 3-year warranty. UNI-T UT211B
SPECIFICATIONS:
AC currents
600mA/6000mA/60A ±(1.5%+10)
60A DC
/>600
A ±(2%+3)
AC voltage
6V/60V/600V ±(0.8%+3)
Direct voltage
600mV/6V/60V/600V ±(0.7%+3)
Resistance
600%+3)
Direct voltage
600 mV/6 V/60 V/600 V ±(0.7% + 3)
Resistance
600%+3) ±(0.8%+2)
Capacitance
6.2 nF–62 mF ±(4%+5)
FUNCTIONS:
Display range 6000
Automatic range
TRMS
Diode test
VFC mode
D
NCVD
D Backlight
Auto power off
Continuity buzzer
Low battery indicator
Input protection
Input impedance DCV 10MΩ+
GENERAL FEATURES:
Power: 2x1.5V AAA batteries
Weight: 170g
Dimensions: 175x60x33mm
Display size: 39.3x26.5mm
ACCESSORIES: Carrying case, batteries, test leads, manual
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210E Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210E – small clamp multimeter
SPECIFICATIONS
AC currents
2A/20A/100A ±(2.5%+5A0)A0
A0
A0 ±(2.5%+3)
AC voltage
2V/20V/200V/600V ±(1%+3)
Direct voltage ±(0.7%+3)
Resistance
200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200kΩ/2MΩ ±(1%+2)
Capacitance
2nF/20nF/200nF/2μF/20μF/200μF/2mF/20mF ±(4%+5)
FUNCTIONS
Display count 2000
J Auto open
17 mm
TRMS
Diode test
NCV
Data hold
Zero mode
Display backlight
Auto power off
Continuity buzzer
Low battery indicator
Input protection
Input impedance DCV/GENERAL+10MΩ/GENERAL> FEATURES
Power: 2x1.5V AAA batteries
Weight: 170g
Dimensions: 175x60x33mm
LCD size: 39x26mm
ACCESSORIES: battery, test leads, carrying case
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT221 Clamp Multimeter
This product comes with a 3-year warranty. UNI-T UT221 Clamp Meter - 2000A
SPECIFICATIONS
AC currents
660A/2000A ±(2.5%/2000A + 60 mA/2000A)
AC CURRENT
±(2.5%+5)
AC voltage
6.6V/66V/660V/1000V ±(1.2%+5)
DC voltage
6.6V/66V/660V/750V ±(0.8%+1)
Resistance
660 Ω/6.6 kΩ/66 kΩ/666 kΩ/6.6 MΩ/66 MΩ ±(1%+2)
Frequency
66 Hz/660 Hz/6.6 kHz/66 kHz/660 kHz/660 kHz/66. ±(0.1%+3)
FUNCTIONS
Display number 6600
Automatic radius
Jaw opening 63mm
TRMS
Duty cycle
Low-pass filter
Ignition current
Relative function
Continuous test
Continuity
Data Hold
Max/min mode
Analogue Bar graph 66
I-OUT function
Display backlight
Logo display
Auto power off
Low battery indication
Input impedance 10MΩ+
GENERAL FEATURES:
Power:
V/>Battery 298x100x48mm
LCD size: 43x30mm
Weight: 725g
ACCESSORIES: Test leads, battery, carrying case, manual
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT216A Clamp Meter
This product comes with a 3-year warranty. UNI-T UT216A
SPECIFICATIONS
AC current 6A/60A/600A ± (2.5%+5)
AC voltage 6V/6V0V/6V/6V0V/6V/60V ±(1.2%+5)
Direct voltage 600mV/6V/60V/600V/1000V ±(0.8%+1)
Resistance 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ ±(1%+2)
Capacitance 99.99 nF/999.9 nF/9.999 μF/99.99 μF/999.9 μF/9.999 mF/59.99 mF ±(4%+5)
FUNCTIONS
Display range 6000
Automatic range
TruJ
TruJ
TruJ RMS
Diode test
NCV
Data hold
Rel/max/min mode
Display backlight
LED torch
Auto-off
Continuity tester
Low battery indicator
Input protection
Input impedance
GENERAL 10MΩ/+DC SPECIFICATIONS
Power 3x 1.5V AAA
Dimensions 220x75x40mm
LCD size 38x24mm
Weight 231.7g
ACCESSORIES: Carrying case, battery, test leads, manual
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT216B Clamp Meter
This product comes with a 3-year warranty. UNI-T UT216B
SPECIFICATIONS
AC current 60A/600A ± (2.5%+5)
AC voltage 6V/60V/7V/60V/7 ±(1.2%+5)
DC voltage 600mV/6V/60V/600V/1000V ±(0.8%+1)
Resistance 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ ±(1%+2)
Capacitance 99.99 nF/999.9 nF/9.999 μF/99.99 μF/999.9 μF/9.999 mF/59.99 mF ±(4%+5)
Frequency 10Hz–1MHz
FUNCTIONS<br/6Automatic display<br/6J00/6J00/6J Capacity 30 mm
True RMS
Diode test
NCV
VFC
Data hold
Rel/Max/Min mode
Display backlight
LED torch
Auto shut-off
Continuity buzzer
Battery charge indicator
DC input indicator
DC input indication
10MΩ+
GENERAL FEATURES
Power 3x 1.5V AAA
Dimensions 220x75x40mm
LCD size 38x24mm
Weight 231.7g
ACCESSORIES: manual, carrying case, battery
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT216C Clamp Meter
This product comes with a 3-year warranty. UNI-T UT216C
SPECIFICATIONS
AC currents 60A/600A ± (2.5%+5)
Direct currents 60A/±200A/600A
AC voltage 6V/60V/600V/750V ±(1.2%+5)
DC voltage 600mV/6V/60V/600V/1000V ±(0.8%+1)
Resistance 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/6MΩ/6MΩ ±(1%+2)
Capacitance 60nF/600nF/6μF/60μF/600μF/6mF/60mF ±(4%+5)
Frequency 10Hz ~ 1MHz ±(0.1%+4)
Temperature -100°C ±(2%+10)*
FUNCTIONS
Display count 6000
Automatic range
Jaw capacity 30mm
True RMS
Diode test
NCV
VCF
Data retention
Minimum current mode/Regraf
Maximum current
Zero 61
Display backlight
LED torch
Auto power off
Continuity buzzer
Low battery indicator
Input protection
DC input impedance 10MΩ+
GENERAL FEATURES
Power 3x 1.5V
Dimensions 220x75x40mm
LCD size 38x24mm
Weight 231.7g
ACCESSORIES: carrying case, test leads, batteries, manual, contact-type temperature probe
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT222 Clamp Multimeter
This product comes with a 3-year warranty.
UNI-T UT222 Clamp Meter - 2500A
SPECIFICATIONS
AC
600A/2500A ±(1)
+5(1). Current
600A/2500A ±(1.5%+5)
AC voltage
6V/60V/600V/1000V ±(1%+3)
Direct voltage
6V/60V/600V/750V ±(0.5%+2)
Resistance
600Ω/6kΩ/60kΩ/600kΩ/6MΩ/600MΩ ±(1%+2)
Frequency
60Hz/600Hz/6kHz/60kHz/600kHz/600kHz/600MHz/600MHz ±(0.1%+3)
Temperature
-40°C ~ 1000°C* ±(1%+10)
FUNCTIONS
Display count 6000
Automatic range
Jaw opening 63mm
TRMS/Pass-band
Pass filter
D Current
Relative function
Diode test
Continuity buzzer
Data hold
Max mode
Analogue Bar graph 61
Data logging 1000
I-OUT function
Display illumination
Iconic display
Power/Auto-off indicator
Power/auto-off indicator 10MΩ+
GENERAL FEATURES
Power supply: 9V alkaline battery
Dimensions: 298x100x48mm
LCD size: 43x30mm
Weight: 725g
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT220 Clamp Meter
This product comes with a 3-year warranty. UNI-T UT220 Clamp Meter - 2000A
SPECIFICATIONS
AC currents
200A/2000A
Accuracy ±5/2% AC. Voltage
2V/20V/200V/1000V
Accuracy ±(1.2%+5)
Direct voltage
2V/20V/200V/750V
Accuracy ±(0.8%+1)
Resistance
200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ
Accuracy ±(1%+2)
FUNCTIONS
Display range 2000
Autorange
Diomm
Autorange Test capacity
Continuity test
Data Hold
Max mode
Display backlight
Signature display
Auto power off
Low battery indicator
Input impedance 10MΩ+
GENERAL FEATURES
Power: 9V battery / Dimensions: 298x100x48mm
LCD size: 43x30mm
Weight: 390g
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT213B Clamp Meter
This product comes with a 3-year warranty. UNI-T UT213B Digital Clamp Meter
* up to 400A
* TRMS
* multifunctional tool for electricians
* practical jaws
* medium-sized jaws
3*mm NCV function
* temperature measurement
* modern input protection
SPECIFICATIONS
AC current 4A/40A/400A ±(1.8%+9)
AC voltage 4V/40V/400V/600V ±(1.2%+5) DC voltage
400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1.0%+2)
Capacitance 40nF/400nF/4μF/40μF/400μF/4mF/40mF ±(4.0%+5%)
Frequency 10Hz–1MHz ±(0.1%+4)
Temperature -40°C–1000°C* ±(Display/Display)
Count 4000
Automatic range
Max. jaw capacity 30mm
True RMS
Diode test
NCV
Data hold
Relative mode
MAX/MIN
LCD backlight
Flashlights
Auto power off
Auto-off indicator
Continuity
Battery indicator Protection
Input impedance for DCV >10MΩ
GENERAL FEATURES
Power: 3x AAA 1.5V
LCD size: 38x24mm
Weight: 280g
Dimensions: 220x75x75x40mm,
CC/>
Test battery Temperature probe, manual, contact type* (up to 230°C)
Manufacturer: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT213A Clamp Meter
This product comes with a 3-year warranty. UNI-T UT213A Digital Clamp Meter
* up to 400A
* multifunctional tool for electricians
* medium-sized jaws
V 30mm* handy flashlight
V
function
* modern input protection
SPECIFICATIONS
AC currents 4A/40A/400A ±(1.8%+9)
AC voltage 4V/40V/400V/600V ±(1.2%+5)
DC voltage 400mV/40V/40V/40V/40V ±(0.8%+1)
Resistance 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1.0%+2)
Frequency 10Hz–1MHz ±(0.1%+4)
FEATURES
Automatic display
awJ00
Automatic display Capacity 30 mm
Diode test
NCV
Data retention
Relative mode
LCD backlight
Flashlight
Auto power off
Continuity buzzer
Low battery indicator
Input protection
Input impedance for DCV >/>
FEATURES
Power: 3x AAA 1.5V
LCD size: 38x24mm
Weight: 280g
Dimensions: 220x75x40mm
ACCESSORIES
Battery, test leads, manual
/>UNI->TREND
/->Manufacturer
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210B Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210B Mini Clamp
* small AC clamp
* sensitive
* input protection
* TRMS
* NCV/ACTION
ACTION
Current
2A/20A/200A ±(1.0%+9)
FEATURES
Display range 2000
TRMS
NCV
MAX/MIN
Relative mode
Jaw capacity 17mm
Data Hold
Auto stop
Auto shut-off
LCD Battery indicator
Input protection
GENERAL FEATURES
Power: 1.5V AAA (2x)
LCD size: 39.3 x 26.5 mm
Weight: 160g
Dimensions: 155 x 60 x 33.5 mm,
Battery
/
Battery Manual
MANUFACTURER: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210A Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210A Mini Clamp
* small AC clamp
* sensitive
* input protection
SPECIFICATIONS
2 AC current/A20A0
±(1.0%+9)
FEATURES
Display range 2000
Jaw capacity 17mm
Data hold
LCD backlight
Auto power off
Low battery indicator
Input protection
TOTAL POWER
TOTAL POWER: (2x)
LCD size: 39.3 x 26.5 mm
Weight: 160g
Dimensions: 155x60x33.5mm
ACCESSORIES
Battery, manual
MANUFACTURER: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT213C Clamp Meter
This product comes with a 3-year warranty. UNI-T UT213C Clamp Multimeter
TECHNICAL SPECIFICATIONS
AC Current (A) 4A/40A/400A
40A+/2.005A+/(DC) (A) 40A/400A ±(2.0%+3)
AC Voltage (V) 4V/40V/400V/600V ±(1.2%+5)
DC Voltage (V) 400mV/4V/40V/400V/600V/400V/600V ±()
Capacitance (F) 50nF/500nF/5μF/50μF/100μF
40nF/400nF/4μF/40μF/400μF/4mF/40mF ±(4.0%+5)
Frequency 10Hz~1MHz ±(0.1%+4)
Temperature (℃) -40~1000℃)(1.0%+±3) -40~1832℉ ±(1.0%+6)
FEATURES
Display count 4000
Auto range √
Max. jaw capacity 30mm
True RMS />Diodes
√ 3.0 V
NCV √
Data hold √
Relative mode √
MAX/MIN √
LCD backlight √
Flashlights √ Auto power off />√ Auto power off
Continuity buzzer √
Low battery indication ≤3.6V √
Input protection √
Input impedance for DCV ≥10MΩ √
GENERAL FEATURES SIZE 5V> AAA 1.
38 mm x 24 mm
Net product weight 231.7g
Product dimensions 220 mm x 75 mm x 40 mm
ACCESSORIES
Battery, test lead, contact-point temperature probe
MANUFACTURER
UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210C Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210C Clamp Meter
TECHNICAL SPECIFICATIONS
AC Current (A) 2A/20A/200A
20A+/200A ±/200A ±/200A
Voltage (V) 2V/20V/200V/600V ±(1.0%+3)
DC Voltage (V) 200mV/2V/20V/200V/600V ±(0.7%+3)
Resistance (Ω) 200Ω/2kΩ/M20kΩ/20kΩ/M200Ω/20kΩ ±(1.0%+2)
Capacitance (F) 20nF/200nF/2μF
/20μF/200μF/2mF/20mF ±(4%+5)
Temperature (℃) -40~1000℃) ±(1℉/+3)
Temperature -40~1832℉ ±(1.5%+5)
FEATURES
Display count 2000
Auto range √
Jaw capacity 17mm
True RMS />V />√ √ A.
NCV √
Auto shut-off: Approx. 15 minutes √
Continuity buzzer √
Low battery indication ≤2.5V √
Data hold √
MAX mode/√ /√ Relative
√
LCD backlight √
Input protection √
Input impedance for DCV ≥10MΩ √
GENERAL SPECIFICATIONS
Power supply: 2 x 1.5V AAA batteries
Net product dimensions LCD 329.3mm> Weight 170 g
Product dimensions 175 mm x 60 mm x 33.5 mm
ACCESSORIES
Battery, test lead, contact-point temperature probe
MANUFACTURER
UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210D Clamp Meter
This product comes with a 3-year warranty. UT210D Clamp Meter
The UT210 series mini clamp meters are designed to perform well in confined spaces. They are essential tools for the maintenance of mechanical and electrical equipment, the installation of household appliances and electrical work.
1. NCV
2. Ergonomic and lightweight
3. Automatic range, sampling rate of 2–3 times per second
4. True RMS
5. ZERO mode
6. LCD backlight, data hold
7. Auto power off, low battery indicator
Specifications: Range
AC current (A): 200A ±(2.5%+8)
DC current (A): 200A ±(2%+3)
AC voltage (V): 600V ±(1%+3)
DC voltage (V/>60)
±(0.7%+3)
Resistance (Ω): 20MΩ ±(1%+2)
Frequency (Hz): 60kHz ±(0.1%+4)
Capacitance (F): 20mF ±(4%+5)
Temperature:
±0°C ±0%+4)
-40~1832℉ ±(1.5%+5)
Features:
Display count: 2000
Continuity buzzer √
Automatic range √
Jaw opening />170 mm
17 mm
General features:
Power: 1.5V battery (R03) x 2
Display: 39.3 mm x 26.5 mm
Product colour: red and grey
Net product weight: 170g
Product dimensions: 175mm x 3.5mm x 3.5mm x 3.5mm Accessories: batteries, test leads, spot contact temperature probe
Standard individual packaging: gift box, English manual, carrying case
Standard quantity per box: 40 pcs
www.uni-trend.com
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT201R Clamp Meter
This product comes with a 3-year warranty. The UT201R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- non-contact electric field detection (NCV)
- Alarm display and visual protection greater than the audible signal/e.g. 600 V in intervals
- automatic range switching
- accuracy guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
4,000 A / 0.001 A / 50 Hz ~ 100 Hz ± (4.0% + 10)
40.00A / 0.010A / 50Hz ~ 100Hz ± 100.0%
(2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10)
- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- Overload protection at 420A.>
AC voltage measurement (range / resolution / accuracy):
4,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5)
40.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5)
600.0V / 1.000V / 10Hz ~ 10kHz ± (0.8% + 5)
- frequency monitoring accuracy when measuring AC voltage within the resolution range from 1.0% ± 5 at 1.0kHz to 0.01 Hz up to 0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% + 3)
4.000 V / 0.001 V / ± (0.5% + 2)
40.00 V / 0.00 V / ±0.3)
400.0V / 0.100V / ± (0.7% + 3)
600 V / 1.000 V / ± (0.7% + 3)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
4. Resistance measurement (range / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% + 2)
4,000 kΩ / 0.001 kΩ / ± (0.8% + 2)
40.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2)
400.0 kΩ / 0.1 kΩ / ± (0.8% + 2)
4,000 MΩ / 0.001 MΩ / ± (2.0% + 5)
40.00MΩ / 0.01MΩ / ± (2.0% + 5) overload protection at 6.0% + 5)
-50 Vrms
5. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
06 overload
-0Ω Vrms
6. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2.0V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 2.2V
- within the 4,000 V measurement range
7. Non-contact electric field sensing (NCV):
- enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz.
Other parameters:
- maximum and minimum measurement value HOLD
- year
- low battery indicator: yes
- auto-off: yes
- 1.5 V battery power supply (R03): 2 pcs
- backlit display size: 37 mm x 25 mm
- product dimensions: 215 mm x 63 mm x 36 mm
- net product weight: 2/4 g
- grey
Package contents:
- UT201R clamp multimeter: 1 pc 40 pcs
- Standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 16.6 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT202F Clamp Meter
This product comes with a 3-year warranty. The UT202F digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 600A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and high-voltage frequency up to 600 V
- non-contact electric field detection (NCV)
- Frequency measurement from 10 MHz to 600 V
60mF
- Measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600V in ranges
- automatic range switching
- accuracy of current and voltage measurements guaranteed within 1% of the technical
parameters:
1. AC current measurement (ranges / resolution / accuracy):
6,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% + 10)
60.00A / 0.010A / 50Hz ~ 100Hz ± 10.0%
(2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10)
- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620A.>
AC voltage measurement (range / resolution / accuracy):
6,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5)
60.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% / 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5)
- frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz overload protection at the input
-0.01kHz overload
-0. approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
600.0 mV / 0.100 mV / ± (0.7% + 3)
6,000 V / 0.001 V / ± (0.5% + 2)
60.00 V / 0.010 V / ±0.7% 3)
600.0 V / 0.100 V / ± (0.7% + 3)
- input impedance approx. 10 MΩ
- overload protection at 600 Vrms
4. Resistance measurement (range / resolution / accuracy):
600.0Ω / 0.1Ω / ± (1.0% + 2)
6,000 kΩ / 0.001 kΩ / ± (0.8% + 2)
60.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2)
600.0 kΩ / 0.1 kΩ / ± (0.8% + 2)
6,000 MΩ / 0.001 MΩ / ± (2.0% + 5)
60.00 MΩ / 0.01 MΩ / ± (2.0% + 5) overload protection at 6.0% + 5)
-50 Vrms
5. Capacitance measurement (ranges / resolution / accuracy):
6,000 nF / 0.001 nF / ± (4.0% + 10)
60.00 nF / 0.01 nF / ± (4.0% + 10)
600.0 nF / 0.00% + 1.10)
6,000 μF / 0.001 μF / ± (4.0% + 5)
60.00 μF / 0.01 μF / ± (4.0% + 5)
600.0μF / 0.1μF / ± (4.0% + 5)
600.0μF / 0.1μF / ± (4.0% + 5). ± 10.0%
60.00 mF / 0.01 mF / ± 10.0%
- overload protection at 600 Vrms
6. Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
Duty cycle: 0.1 to 99.9% / 0.1% / ± 5.0% / ± 5.0% Measurement sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
>1 V RMS input
> 1 V RMS: amplitude ≤ 30 V RMS
- Note 2) Duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95% Duty cycle: 30.0% ~ 70.0%
- Overload protection at 600 V rms
7. Circuit continuity check:
- if the measured resistance is less than 10Ω, the continuity circuit signal triggers a buzzer
- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
60-0Ω during overload
Vrms
8. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.9V
- measurement range of 6.000V
Parameters:
- measurement of maximum and minimum values: yes
- Relative mode (ratio) measurement for voltage and capacitance: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- 1.5 V battery power supply (backlit display size: 3 x 3): 25 mm
- Product dimensions: 215 mm x 63 mm x 36 mm
- net product weight: 248 g
- Product colour: red and grey
Package contents:
- UT201R clamp multimeter: 1 pc. test leads
/>- 1 pc. (R03): 2 pcs
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight per box: 16/F: 7 kg
https://www.uni-trend
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT202R Digital Clamp Meter
This product comes with a 3-year warranty. The UT202R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- non-contact electric field detection (NCV)
- Temperature measurement from -1/>-°C to -100°C, multi-segment display and audible/visual alarm
- protection against voltages exceeding 600 V in intervals
- automatic range switching
- accuracy guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
4,000 A / 0.001 A / 50 Hz ~ 100 Hz ± (4.0% + 10)
40.00A / 0.010A / 50Hz ~ 100Hz ± 2.0%/100Hz ± (4.0% +10) 0.100 A / 50 Hz ~ 100 Hz ± (2.0% +10)
- the frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 420 A
>
AC voltage measurement (range / resolution / accuracy):
4,000 V / 0.001 V / 10 Hz to 10 kHz ± (1.0% + 5)
40.00 V / 0.010 V / 10 Hz ~ 10 kHz ± (0.8% / 0.8% +5) / 10 Hz ~ 10 kHz ± (0.8% +5)
600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to ± 10 kHz at a resolution of + (10 kHz). 0.01 Hz to 0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% +3)
4.000 V / 0.001 V / ± (0.5% +2)
40.00 V / 0.010 V / 0.010 V / 0.010 V / ± (0.7% +3) 0.100 V / ± (0.7% +3)
600 V / 1,000 V / ± (0.7% +3)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
4. Resistance measurement (ranges / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000 kΩ / 0.001 kΩ / ± (0.8% +2)
40.00 kΩ / 0.01 kΩ / 0.01 kΩ / ±40.8 kΩ / ±2.0 kΩ / 0.1 kΩ / ± (0.8% +2)
4,000 MΩ / 0.001 MΩ / ± (2.0% +5)
40.00 MΩ / 0.01 MΩ / ± (2.0% +5)
- overload protection at 600 Vrms
>
Capacitance measurement (ranges / resolution / accuracy):
4,000 nF / 0.001 nF / ± (4.0% +10)
40.00 nF / 0.01 nF / ± (4.0% +10)
400.0 nF / ±4 nF / ±4 nF / ±4 nF (0.01 nF / ± (4.0% +10) +10)
4,000 μF / 0.001 μF / ± (4.0% +5)
40.00 μF / 0.01 μF / ± (4.0% +5)
400.0 μF / 0.1 μF / ± (4.0% +5.0,01 μF / 0.01 μF / ± (4.0% +5)) 10.0%
- overload protection at 600 Vrms
6. Temperature measurement (ranges / resolution / accuracy):
-40°C to +40°C/1°C / ±4°C
+40°C to +500°C/1°C/ ±(1.5% +5)
+500°C to +1000°C/±(2°C/1°C/±(1.5% +5) +5)
-40°F to +104°F/1°F/± 6°F
+104°F to +932°F/1°F/ ± (2.0 +6)
+932°F to +1832°F/1°F/ ± (2.5% +4/7)
Circuit continuity check:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31 ohms, the open circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
06 overload
-0Ω Vrms
8. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 2.2V
- measurement in the 4.900 V range
/>
Non-contact electric field sensor (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz
Other parameters:
Measurement value:
HOLD: Yes
- low battery indication: Yes
- Auto-off: Yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 215 mm x 63 mm x 36 mm
- Net product weight:
- 24 g Product colour:24-8 g grey
Package contents:
- UT202R clamp multimeter: 1 pc Box: 40 pcs
- Standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 17.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT203R Clamp Multimeter
This product comes with a 3-year warranty. The UT203R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 400A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- measurement of frequencies from 10 Hz to 10 MHz
- Measurement capabilities
-400V
- 40 mF
- measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600V in intervals
- non-contact detection of live conductors
- automatic range switching
- measurement accuracy of current and voltage is guaranteed to within 1% across 10% of ranges
Technical parameters:
1. AC measurement (ranges / resolution / accuracy):
40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5)
400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) current monitoring accuracy ± 5) the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620 A
2. DC current measurement (ranges / resolution / accuracy):
40.00A / 0.010A / ± (2.0% +5)
400.0 A / 0.100 A / ± (2.0% + 5)
- overload protection at 620 A
>
>
4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.8% +5) / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10Hz to 60kHz at a resolution of ±0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
4. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% +3)
4.000 V / 0.001 V / ± (0.5% +2)
40.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2)
600.0V / 1V / ± (0.5% +2)
- input impedance approx. 10MΩ
- Overload protection at 600 Vrms
5. Resistance measurement (ranges / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000 kΩ / 0.001 kΩ / ± (0.8% +2)
40.00kΩ / 0.01kΩ / 0.01kΩ / ±2.0% 0.8kΩ / ±2.0kΩ / 0.1kΩ / ± (0.8% +2)
4.000 MΩ / 0.001 MΩ / ± (2.5% +5)
40.00 MΩ / 0.01 MΩ / ± (2.5% +5)
- overload protection at 600 Vrms open circuit
- approx. 1V
6. Capacitance measurement (range / resolution / accuracy):
40.00 nF / 0.01 nF / ± (4.0% +5)
400.0 nF / 0.1 nF / ± (4.0% +5)
4.000 μF / 0.001 μF / ± (4.0% +5)
40.00 μF / 0.01 μF / ± (4.0% +5)
400.0 μF / 0.1 μF / ± (4.0% +5)
4,000 μF / 0.001 μF / ± 10.0%
- overload protection at 600 Vrms
7. Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
Duty cycle: 0.1 to 99.9% / 0.1% / ± (5)
Note/+5. Sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
> 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS
- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency
Operating frequency
1 kHz 30.0% ~ 70.0%
- overload protection at 600 Vrms
8. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31Ω, the open circuit signal does not emit a buzzer
- uncertainty in the range from 10Ω to 31Ω. 600Ω range
- Overload protection at 600 Vrms
9. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 4.0V
- measurement in the range of 6.000V
Non-contact voltage detection (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz
Other parameters:
- Measurement of maximum and minimum values (ratio) for voltage and capacitance: yes
- HOLD: yes
- low battery indicator: yes
- Auto-off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 63 mm
- x 63 mm
- net product weight: 235 g
- product colour: red and grey
Package contents:
- UT204R clamp multimeter: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 2 pcs user manual
- 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 16.1 kg
MANUFACTURED BY UNIVERSITATEA www.
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT204R Clamp Multimeter
This product comes with a 3-year warranty. The UT204R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on low-voltage distribution lines in CAT II. With the included Type K thermocouple (nickel-chromium-nickel-silicon temperature sensor), it allows temperature measurement from -40°C to 1000°C. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is <11μA, which effectively extends the battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and high-voltage frequency up to 600 V
- frequency measurement from 10 Hz to 10 MHz
- Measurement capabilities
- 60 mF
- Temperature measurement from -40 to +1000 °C
- Measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600 V in intervals
- Non-contact detection of live voltages and switching accuracy of live conductors
-
guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5)
600.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) The accuracy of AC frequency monitoring in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620 A
2. DC current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / ± (2.0% + 5)
600.0 A / 0.100 A / ± (2.0% + 5)
- overload protection at 620 A
>
>
6,000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
60.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.0% +5) / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to 60 kHz ± (0.5% + 2) at a resolution of 0.01 Hz to 0.01 kHz
- input overload protection
- 0.01 kHz
- overload protection
- 60/0 V rm. 10 MΩ
4. DC voltage measurement (range / resolution / accuracy):
600.0 mV / 0.100 mV / ± (0.7% +3)
6,000 V / 0.001 V / ± (0.5% +2)
60.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
5. Resistance measurement (ranges / resolution / accuracy):
600.0Ω / 0.1Ω / ± (1.0% +2)
6,000 kΩ / 0.001 kΩ / ± (0.8% +2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / 60.8 kΩ ±2.0 kΩ 0.1 kΩ / ± (0.8% +2)
6,000 MΩ / 0.001 MΩ / ± (2.5% +5)
60.00 MΩ / 0.01 MΩ / ± (2.5% +5)
- overload protection at 600 Vrms open circuit
- approx. 1V
6. Capacitance measurement (ranges / resolution / accuracy):
60.00 nF / 0.01 nF / ± (4.0% +5)
600.0 nF / 0.1 nF / ± (4.0% +5)
6000 μF / 0.001 μF / ±4.0% +5)
60.00 μF / 0.01 μF / ± (4.0% +5)
600.0 μF / 0.1 μF / ± (4.0% +5)
6,000 mF / 0.001 mF / ± 10.0%
- overload protection at 600 Vrms
7. Temperature measurement (ranges / resolution / accuracy):
-40°C to +40°C / 1°C / ± 4°C
+40°C to +500°C/1°C / ± (1.5% +5)
+500°C to +1000°C/±2°C/1.5°C
-40°F to +104°F / 1°F / ± 6°F
+104°F to +932°F / 1°F / ± (2.0 +6)
+932°F to +1832°F / 1°F / ± 4
%
Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% +4)
load: 0.1 to 99.9% / 0.1% / ±5)
Note/+5. Sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
> 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS
- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency
Operating frequency
1 kHz 30.0% ~ 70.0%
- Overload protection at 600 Vrms
9. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31Ω, the open-circuit signal does not emit a buzzer
- uncertainty in the range from 10Ω to 31Ω. 600Ω range
- Overload protection at 600 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 4.0V
- measurement in the range of 6.000V
Non-contact electric field sensing (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz
Other parameters:
- measurement of maximum and minimum values
- relative measurement of maximum and minimum. Mode (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 631.5 mm x 631 mm
- net product weight: 235 g
- Product colour: red and grey
Package contents:
- UT204R clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 101 V: 0 pcs
(R03): 2 pcs
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight per box: 16/F: 7 kg
https://www.uni-trend.com/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT205E Clamp Multimeter
This product comes with a 3-year warranty. The UT205E digital clamp meter is used for measuring AC and DC voltages up to 1000 V, AC currents up to 1000 A and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum displayable value is 6000. The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive inductive current loop. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends the battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and AC current, resistance, diodes, continuity, capacitance
- automatic polarity display
- current frequency measurement in the range from 40 to 60 Hz and up to low voltages (10 Hz) V0040 at 400 Hz
- Measurement of low-voltage frequency (mn) in the range from 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- Measurement of the (relative) ratio of voltages and capacitances
- Multi-segment display and audible/visual protection against voltages exceeding 100 V - Intervals
- NCV function – non-contact detection of live conductors
- Frequency/duty cycle measurement function
- Choice of automatic or manual range switching
- Built-in lamp
- Accuracy of current and voltage measurement is guaranteed when using the range within the 5% to 100% range; no adjustment of the 5% to 100% range is required
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 60Hz is ± (0.1% + 3) at a resolution of 0.1Hz
- Overload protection at 1000A
2. AC voltage measurement (range / resolution / accuracy):
6,000 V / 0.001 V / 40 Hz ~ 400 Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
3. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5% + 3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5% + 3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
4. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
5. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
6. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
7. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6.000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
8. Frequency measurement and duty cycle (duty)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
duty cycle: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
9. Non-contact electric field sensor (NCV):
- enables the detection of live wires - as the detected voltage increases, the buzzer will sound at a higher volume and the LED will begin to flash.
Other parameters:
- measurement of maximum and minimum values: yes
relative capacitance measurement mode: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- Powered by 1.5 V batteries (R03): 2 pcs
- backlit display size: 43 x 45 mm
- Product dimensions: 272 x 81 x 43.5 mm
- Net product weight
- 43.5 mm
colour: red and grey
Package contents:
- UT205E clamp multimeter: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 3 pcs
- user manual: 1 pc
>
Standard box packaging: 10 pcs
- standard box dimensions: 355 mm x 330 mm x 315 mm
- standard gross weight of box: 7.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT206B Clamp Multimeter
This product comes with a 3-year warranty. The UT206B digital clamp meter is used to measure AC and DC voltages up to 1000 V, AC currents up to 1000 A, and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive inductive current loop. Option to purchase a flexible loop for measuring currents up to 3000 A. Power supply: 3 x 1.5 V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and AC current, resistance, diodes, continuity, capacitance
- automatic polarity display
- measurement of frequency of low-voltage (LV) currents and voltages up to 1000–40 V/Hz
measurement of low-voltage (LV) frequency in the range 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- temperature measurement from -40 to +1000 °C with a closed K-type thermocouple
- Measurement of the (relative) ratio of voltages and capacitances for alarm and multiple alarms – e.g. protection against voltages exceeding 1000 V in intervals
- NCV function – non-contact detection of live conductors
- LoZ V function – measurement with low input impedance (approx. 2 kΩ) of the device
- INRUSH function – measurement of transients up to 100 ms – with an additional start-up duration of up to 30,000 A. loop
- LPF ACV function – AC voltage measurement with low-pass filter (approx. 2.5 kHz) on inverters and variable-frequency drives
- Frequency/duty cycle measurement function
- Choice between automatic or manual switching
- Built-in lamp
- Current and voltage accuracy are guaranteed when current and voltage measurement is within 10% of the value; if the value falls outside this range, the range must be changed
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz
- Overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.000Hz / 40.010Hz ±(10.0%+10)
300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection
-10 3000A
3. AC voltage measurement (range / resolution / accuracy):
6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3)
60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
4. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ
5. AC LPF V (measurement with low input impedance approx. 2 kΩ)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
- Input overload protection rm approx. 2kΩ
6. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5%+3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
7. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
8. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
9. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0 V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
10. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6,000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
11. Temperature measurement
(ranges / resolution / accuracy):
-40°C to +300°C / 0.1°C / ± 1.0°C+20
+300°C to +1000°C / 1°C / ±(1.0%+2)
+573°F to +1832°F / 1°F / ±(1.0%+4)
12. Frequency measurement and operating cycle (filling)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
Fill: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
13. Non-contact electric field sensing (NCV):
- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- Auto power off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 43 x 45 mm
- Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 492g
- Product colour: red and grey
Package contents:
- UT206B clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 1000°C: 1 pc
3:
>-R<03/> user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 10 pcs
- standard box dimensions: 355 mm x 330 mm x 315 mm
- standard gross weight per box: 7.1 kg
MANUF UNI-TREND
https://www.uni-trend.com/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT207B Clamp Meter
This product comes with a 3-year warranty. The UT207B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 10,000,000 V in the range of 1,000,000 V at 400 Hz and low voltage (LV) from 10 Hz to 1 MHz. It features protection against voltages exceeding 1,000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance
- automatic polarity display
- measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range from 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- Measurement of the (relative) ratio of voltages and capacitances
- Multi-segment display and audible/visual alarm
- protection against voltages higher than 10V/0V - contact function without NC
- live conductors
- LoZ V function ~ measurement with low input impedance (approx. 2kΩ) of the device
- INRUSH function – measurement of transients up to 100 ms in length – inrush current at device start-up up to 3000 A with additional flexible loop
- LPF ACV measurement function on nf2H5 filter (approx. inverters and variable frequency drives
- Frequency/duty cycle measurement function
- Choice between automatic or manual range switching
- Built-in lamp
- Accuracy of current and voltage measurement is guaranteed when using the range between 5% and 100% of the full scale; at 5% of the full scale, a technical adjustment is required
>
Parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz
- Overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.000Hz / 40.010Hz ±(10.0%+10)
300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection
-10 3000A
3. DC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / ±(2.0%+5)
600.0A / 0.100A / ±(2.0%+5)
1000.0A / 1A / ±(2.0%+5) overload protection
2.0%/>-5 1000A
4. AC voltage measurement (range / resolution / accuracy):
6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3)
60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ
6. AC LPF V (measurement with low input impedance approx. 2 kΩ)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
- Input overload protection rm approx. 2kΩ
7. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5%+3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
8. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
9. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
11. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6,000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
12. Frequency measurement and duty cycle (duty)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
duty cycle: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
13. Non-contact electric field sensing (NCV):
- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- Auto power off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 43 x 45 mm
- Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g
- Product colour: red and grey
Package contents:
- UT207B multimeter clip: 1 pc
- Test leads: 1 pair
- 1.5 V battery (R03): 3 pcs
- user manual
- 1 pc
- user manual
Packaging:
- standard quantity per box: 10 pcs
- standard box dimensions: 355 mm x 330 mm x 315 mm
- standard gross weight per box: 7.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend