{"product_id":"deye-80kw-three-phase-on-grid-inverter-sun-80k-g03","title":"DEYE 80kW Three-Phase On-Grid Inverter, SUN-80K-G03","description":"\u003cp\u003e\u003ca href=\"https:\/\/www.v-tac.eu\/images\/certificates\/Technical-Specs\/SUN-70-75-80-90-100-110K-G03-Technical-Specs.pdf\"\u003e\u003cspan\u003eDownload Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.v-tac.eu\/images\/certificates\/Manual\/SUN-70-75-80-90-100-110K-G03-Manual.pdf\"\u003e\u003cspan\u003eDownload User Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe DEYE SUN-80K-G03 converts the energy generated by photovoltaic panels into three-phase electrical energy compatible with 380\/400V utility grids. Its rated output power of 80kW makes it suitable for large commercial and industrial installations.\u003c\/p\u003e\n\u003cp\u003eThe maximum supported photovoltaic power is 104kW. Its four MPPT trackers, each with four string inputs, provide flexible PV array connection and management, including installations where groups of panels have different orientations or irradiation conditions.\u003c\/p\u003e\n\u003cp\u003eThe MPPT operating range is 200–850V, while the maximum input voltage is 1000V. The maximum operating current is 40A per MPPT, while the maximum short-circuit current is 60A per MPPT.\u003c\/p\u003e\n\u003cp\u003eThe inverter offers a maximum efficiency of 98.7%, an IP65-rated enclosure and intelligent air cooling. RS485 and RS232 interfaces enable monitoring-system integration, while GPRS, Wi-Fi, Bluetooth, 4G or LAN connectivity is available through optional modules.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e80kW rated output power\u003c\/li\u003e\n\u003cli\u003e88kVA maximum apparent power\u003c\/li\u003e\n\u003cli\u003e104kW maximum photovoltaic power\u003c\/li\u003e\n\u003cli\u003eFour MPPT trackers\u003c\/li\u003e\n\u003cli\u003e16 string inputs, with four inputs per MPPT\u003c\/li\u003e\n\u003cli\u003e200–850V MPPT operating range\u003c\/li\u003e\n\u003cli\u003e1000V maximum input voltage\u003c\/li\u003e\n\u003cli\u003e40A + 40A + 40A + 40A maximum operating current\u003c\/li\u003e\n\u003cli\u003e98.7% maximum efficiency\u003c\/li\u003e\n\u003cli\u003e98.1% European efficiency\u003c\/li\u003e\n\u003cli\u003eIP65-rated enclosure\u003c\/li\u003e\n\u003cli\u003eIntelligent air cooling\u003c\/li\u003e\n\u003cli\u003eType II DC and AC surge protection\u003c\/li\u003e\n\u003cli\u003eZero Export function with compatible equipment\u003c\/li\u003e\n\u003cli\u003eSmart string monitoring – optional\u003c\/li\u003e\n\u003cli\u003eAnti-PID function – optional\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003ch4\u003eHigh Output for Commercial Applications\u003c\/h4\u003e\n\u003cp\u003eThe 80kW rated output allows the inverter to be used in photovoltaic systems installed on industrial buildings, warehouses, manufacturing facilities and commercial buildings.\u003c\/p\u003e\n\u003ch4\u003eFlexible PV Array Management\u003c\/h4\u003e\n\u003cp\u003eThe four MPPT trackers allow the panels to be divided into independently managed groups, helping optimise production when panel orientations or operating conditions differ.\u003c\/p\u003e\n\u003ch4\u003eFlexible DC-to-AC Ratio\u003c\/h4\u003e\n\u003cp\u003eThe maximum photovoltaic power of 104kW allows the PV array to be larger than the inverter’s rated AC output, subject to the manufacturer’s limits and requirements.\u003c\/p\u003e\n\u003ch4\u003eIntegrated Protection Functions\u003c\/h4\u003e\n\u003cp\u003eThe inverter includes protection against DC reverse polarity, overcurrent, overvoltage, short circuits, excessive temperature, insulation faults, residual current and unintended island operation.\u003c\/p\u003e\n\u003ch4\u003eRemote Monitoring\u003c\/h4\u003e\n\u003cp\u003eThe connectivity options enable production and operating parameters to be monitored through compatible platforms.\u003c\/p\u003e\n\u003ch3\u003eRecommended Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial buildings and premises\u003c\/li\u003e\n\u003cli\u003eFactories and manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eWarehouses and logistics centres\u003c\/li\u003e\n\u003cli\u003eCommercial buildings\u003c\/li\u003e\n\u003cli\u003eBusiness centres\u003c\/li\u003e\n\u003cli\u003eFarms and agricultural facilities\u003c\/li\u003e\n\u003cli\u003eCommercial photovoltaic power plants\u003c\/li\u003e\n\u003cli\u003eThree-phase grid-connected systems\u003c\/li\u003e\n\u003cli\u003eInstallations requiring energy export limitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 100.014%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003eGeneral Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eDEYE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eSUN-80K-G03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eV-TAC Product Code\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e12724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eInverter Type\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eOn-grid, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eTransformerless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003ePhotovoltaic Input – DC\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum Photovoltaic Power\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e104kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eStart-Up Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMPPT Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e200–850V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum PV Operating Current\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e40A + 40A + 40A + 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum PV Short-Circuit Current\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e60A + 60A + 60A + 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMPPT Trackers \/ Strings per MPPT\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e4 \/ 4 + 4 + 4 + 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003eGrid Output – AC\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eRated Active Power\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e80kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum Apparent Power\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e88kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eRated AC Voltage \/ Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e220\/380V or 230\/400V; 0.85Un–1.1Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eGrid Connection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eRated AC Current\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e121.2A at 380V \/ 115.9A at 400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum AC Output Current\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e133.3A at 380V \/ 127.5A at 400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eRated Frequency \/ Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e50Hz \/ 45–55Hz; 60Hz \/ 55–65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003ePower Factor Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eTotal Harmonic Distortion (THDi)\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eDC Current Injection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003eEfficiency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e98.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eEuropean Efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e98.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMPPT Efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e\u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eDC Reverse-Polarity Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eAC Overcurrent and Overvoltage Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eAC Short-Circuit Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eThermal Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eInsulation Impedance Detection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eDC Component Monitoring\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eAnti-Islanding Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eResidual Current Detection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eSurge Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eType II DC \/ Type II AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eDC Switch\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eAFCI Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003eGeneral Characteristics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eIngress Protection Rating\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e-25°C to +60°C, with power derating above +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003ePermissible Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e4000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e≤55dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e824 × 516 × 312.7mm, excluding connectors and mounting brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e81kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eOVC II DC \/ OVC III AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 99.7198%;\"\u003eCommunication and Compliance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eRS485 \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eOptional Monitoring\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eGPRS, Wi-Fi, Bluetooth, 4G or LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eReferenced Grid Standards\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G99, VDE-AR-N 4105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eSafety and EMC Standards\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/2\/3\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7314%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 63.9884%;\"\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eCompatibility and Important Information\u003c\/h3\u003e\n\u003cp\u003eThis is an on-grid inverter. It does not have a battery input and does not provide backup power when the utility grid is unavailable.\u003c\/p\u003e\n\u003cp\u003eThe Zero Export function requires a compatible meter or metering system that has been correctly installed and configured.\u003c\/p\u003e\n\u003cp\u003eSmart string monitoring, Anti-PID, AFCI protection and wireless communication modules are optional. Their inclusion must be checked in the supplied commercial configuration.\u003c\/p\u003e\n\u003cp\u003eThe maximum photovoltaic power of 104kW must not be confused with the rated AC output power of 80kW.\u003c\/p\u003e\n\u003cp\u003eThe PV strings must be sized according to the panels’ Voc, Vmp, Isc and Imp values, the limits of each MPPT tracker and the minimum and maximum temperatures at the installation site.\u003c\/p\u003e\n\u003cp\u003eCompatibility with the distribution system operator’s requirements and the regulations applicable to the project must be checked before purchase.\u003c\/p\u003e\n\u003cp\u003eInstallation, configuration and commissioning must be carried out by qualified personnel in accordance with the manufacturer’s instructions and all applicable regulations.\u003c\/p\u003e","brand":"DEYE","offers":[{"title":"Default Title","offer_id":58034086281547,"sku":"SUN-80K-G03","price":2580.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/sun-70-100k-g03-3phase-deye-1_25bdc6c5-0316-45fc-8933-35c0985839f6.png?v=1781007946","url":"https:\/\/solar-tech.it\/products\/deye-80kw-three-phase-on-grid-inverter-sun-80k-g03","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}